    Please start the Diode-pumped solid-state laser according to the following steps:

1) Remove the covers at the ends of Nd:YAG rod. Check the crystal ends, if there is dust attached to it, please clean it before starting the Diode-pumped solid-state laser module.

2) Position the laser module on the optic rail and make sure that the beam output is in parallel. Position the high reflection(HR) mirror and output coupler(OC) and adjust them with pilot beam into an optical resonator. The distance between HR and OC can be adjusted by users.

3)  Connect the cooling water pipe and make sure the water flow is smooth.

4) Connect the matched laser diode driver: red line is with anode, black line is with cathode. The laser module must be driven by professional laser diode driver(we supply matched Diode-pumped solid-state laser driver), if you are using other supplier’s laser diode driver, please contact us in advance to get permission.

5)  Connect the protection wire of the water cooler to the laser diode driver, and connect the temperature monitoring signal line ofDiode-pumped solid-state laser module to the laser diode driver.

6) Start the water cooler(adjust the target temperature 20-25℃ ), make sure the water flow rate is enough.

7) Start the laser diode driver, increase the current slowly till the recommended operation current.

8) When the operation is over, please turn down the current slowly till the minimum value, then shut down the laser diode driver, and then shut down water cooler.


1. Full sealed in nitrogen atmosphere, high environmental adaptability and stability

2. Temperature supervisory system design, double-layer protection

3. High stability of power, uniform circular spot

4. Used industry standard parts, high generality

5. Easy water cooling system, low demands on water quality

6. High performance cost ratio

Marking,Cutting,Welding

parameters

DPL-50

DPL-75

DPL-100

Central wavelength

1064nm

1064nm

1064nm

Output power

≥50W

≥75W

100w

YAG diameter

3mm

3mm

3mm

YAG length

67mm

67mm

90mm

YAG central height

40mm

40mm

40mm

Operating current

18A

18A

18A

Maximum driving voltage

20V

30V

35V

Maximum driving current

20A

20A

20A

Best cooling water temperature

20

20

20

Best working temperature

1030

1030

1030

Storage temperature

570non-freezing

570non-freezing

570non-freezing

Working environment moisture

Non-condensing

Non-condensing

Non-condensing

Notice: (1) If customers have special request on laser output central height, for module with 40+5mm or 40+10mm can be customized.

(2) The cavity length of 75W is recommended to be under 400mm(distance between output mirror and total refractive mirror).